What does it cost to heat a room in a Victorian house?

Work out what a room actually loses in heat, the heater size it needs, and what holding it at a comfortable temperature costs per hour, per month and across a winter.

Using the Spanish average of 26.69c/kWh — Eurostat, the second half of 2025.

Solid walls, tall ceilings and generous windows — three things that each raise the bill, in one room.

The room
m²
Length times width. A typical UK living room is around 16 m²; a double bedroom around 12 m².
m
2.4 m (8 ft) in most modern homes. Victorian rooms are often 3 m or more, which is a fifth more air to heat.
Only walls facing outdoors count. A wall shared with a heated room, or with a neighbour's heated room, loses almost nothing.
m²
Total glazing, frames included. A standard domestic window is roughly 1.2 × 1.2 m, so about 1.5 m².
A ceiling under a heated bedroom loses nothing. A ceiling under a cold loft is often the biggest single loss in the room.
How it is built
Describes the construction, not the era — the same wall was normal in different decades in different countries. The exact U-values behind each option are listed in the assumptions below.
Heating it
°C
18 to 21 °C covers most people. Every degree costs roughly 7 to 10% more, because it widens the gap the heat has to bridge.
°C
Defaults to the average outdoor temperature on days your country needs heating at all. Drop it to freezing to see a cold snap.
%
100 for any plug-in electric heater — fan, oil-filled, panel, halogen or infrared, all identical on this measure. Use 300 to 400 for an air-to-air heat pump or an air conditioner running in heat mode.
hours
Time the heater is actually delivering heat. A thermostat cycling on and off counts only the time it is on.
c/kWh
From your bill, per kilowatt hour. Defaults to the current published figure for your country.
Cost for a winter €232
Heat this room loses 872
Heater size needed (kW) 1
Cost per hour €0.23
Cost per day €1.40
Cost per month €42.51
Electricity per day 5.2 kWh
Heat loss per degree (W/K) 90.9

What drives the cost

A period room stacks three penalties on top of each other. Solid walls with no cavity lose heat around two and a half times faster than an insulated cavity wall. Ceilings at three metres or more mean a fifth to a third more air in the room to keep warm, and the warmest of it sits above head height doing nobody any good. And the windows are generous, frequently single-glazed, and set in frames that have moved over a century of seasons.

The order of attack is not the obvious one. Draught-proofing comes first and costs almost nothing — sash windows, floorboards, skirtings and an unused chimney can together account for a large share of the loss, and an open chimney alone can empty a room several times an hour. Secondary glazing generally beats replacement windows in a period property on both cost and appearance. Internal or external wall insulation transforms the room but is expensive and needs care, because solid walls have to stay able to dry outwards or you trade a heating problem for a damp one.

How this is worked out

A room loses heat through every surface facing somewhere colder, and through the air that leaks out and has to be warmed again. Each surface loses in proportion to its area, how well it insulates, and how much colder it is outside. Add those together and you get a heat loss coefficient — watts per degree — which belongs to the room alone and does not change with the weather. Multiply it by the temperature difference you want to hold and you have the heat the room needs. For a plug-in electric heater that is exactly the electricity it draws, because a resistive heater turns all of its electricity into heat. Nothing about this is brand-specific: a £15 fan heater and a £300 designer panel of the same wattage cost precisely the same to run.

What this assumes

  • U-values for walls, roofs and windows are the published defaults from BRE's RdSAP 10 specification (February 2024) and consultation paper CONSP:16. Those are in-situ measured figures — the solid-brick default was cut from 2.1 to 1.7 W/m²K after fieldwork found real walls beat the theoretical calculation. The five options above use, in order: walls 1.7, 1.5, 0.7, 0.30 and 0.18; windows 4.8, 2.8, 2.0, 2.0 and 1.4; roofs 0.68, 0.40, 0.16, 0.16 and 0.11.
  • Floor U-values (0.7, 0.7, 0.45, 0.22, 0.13) and air change rates (1.2, 1.0, 0.7, 0.55, 0.4 per hour) are representative rather than measured. A real floor depends on the ratio of exposed perimeter to area, and real air leakage depends on chimneys, flues and how sheltered the building is — neither is knowable from the questions above, and both are the largest source of uncertainty here.
  • The room is assumed square. A long thin room of the same floor area has more external wall and so loses more: 2 × 8 m has a 20 m perimeter against 16 m for 4 × 4 m, and this would under-read it by roughly a quarter.
  • Only surfaces facing unheated space are counted. Walls to a heated neighbour, and ceilings under heated rooms, are treated as losing nothing — close enough in practice, though a wall to a neighbour who never puts the heating on is not.
  • Nothing is credited for heat you get free. People, cooking, lighting, appliances and winter sun through a south-facing window all add real warmth — often 200 to 400 W in an occupied living room — so a real bill usually lands below the figure here.
  • The seasonal figure multiplies the daily cost by the number of days a year your country needs heating at all, at the average outdoor temperature for those days. It is a fair estimate of a whole winter, not a prediction of any particular one.
  • The rate filled in for you is an average that spreads fixed charges across a year's usage, so it sits above what one extra unit really costs. Entering the unit rate from your own bill gives a closer answer.

Questions

Are solid walls really that much worse?

Yes, though less than was long assumed. The accepted figure was 2.1 W/m²K until in-situ measurement of real houses found they perform better than the calculation predicted, and the default was cut to 1.7. That is still around two and a half times an insulated cavity wall, but it also means the savings from insulating them were historically overstated.

Should I get secondary glazing or replace the windows?

In a period property, usually secondary glazing. It performs comparably to modern double glazing, costs considerably less, keeps the original windows and their appearance, and is often the only option permitted in a listed building or conservation area. It also helps more with noise than replacement units do.

Do high ceilings really cost more to heat?

Yes, through two routes. There is more air to warm, which shows up in the ventilation part of the calculation, and there is more external wall area for the same floor area. Warm air also stratifies, so the top of a three-metre room can sit several degrees above head height — heat you are paying for and not feeling. This is the one case where a ceiling fan run slowly in reverse genuinely earns its keep.

Are some electric heaters cheaper to run than others?

No. Every plug-in electric heater is 100% efficient at the point of use — fan, oil-filled, convector, panel, halogen and infrared alike. A 2 kW heater of any type uses 2 kWh an hour and costs the same. What differs is how the heat feels and how quickly it arrives: infrared warms objects and people directly so it can feel effective sooner, and an oil-filled radiator keeps releasing heat after it switches off. Neither changes the meter reading. Anything advertised as a cheap-to-run electric heater is either a heat pump or a claim worth ignoring.

Is it cheaper to leave the heating on low all day?

No, and the physics above is why. A room loses heat in proportion to how much warmer it is than outside, so a room kept warm all day spends every one of those hours losing heat. Letting it cool means a smaller temperature difference for most of the day and therefore less total loss. Reheating costs something, but less than the standing loss it avoids. The exception is a home so damp that letting it go cold invites condensation, which is a different problem with a different fix.

Why is my conservatory so expensive to heat?

Because almost all of it faces outside. Glass loses heat several times faster than an insulated wall, a conservatory usually has three glazed walls plus a glazed or thin roof, and its floor sits over cold ground. Put a conservatory's numbers in above and the heat loss often comes out three or four times a normal room of the same size. The honest answer is usually to heat it only when it is in use, and to accept it as a spring and autumn room.

Should I heat one room instead of the whole house?

Often yes, if the rest of the house genuinely stays unheated and you accept it being cold. Heating one room costs roughly what this calculator says; heating a whole house costs the same arithmetic repeated for every room, plus the corridors between them. The catch is that unheated rooms get cold surfaces, and cold surfaces attract condensation and then mould. If you go down this route, ventilate the cold rooms rather than sealing them up.

How much does turning the thermostat down by one degree save?

Roughly 7 to 10% of the heating bill for that room, and you can see it in the maths: cost is proportional to the gap between inside and outside. Holding 20 °C against 8 °C is a 12-degree gap; holding 19 °C is 11 degrees, which is 8% less. The saving is bigger in a mild climate, because one degree is a larger share of a smaller gap — which is also why the same advice is worth more in Portugal than in Finland.

Is an air-to-air heat pump worth it for one room?

On running cost, usually yes and by a lot. A heat pump does not make heat, it moves it, so it delivers three to four units of heat per unit of electricity — set efficiency to 350 above and the bill falls by about two thirds. Against that sits the installation cost, which is thousands rather than tens, so the sum turns on how many hours a year you actually heat that room. A room heated all winter pays it back; a spare bedroom heated at Christmas does not.